2 edition of Study of 127 electrostatic cylindrical analyser and application to energy analysis of ion guns found in the catalog.

Study of 127 electrostatic cylindrical analyser and application to energy analysis of ion guns

S. Sadek

Study of 127 electrostatic cylindrical analyser and application to energy analysis of ion guns

dissertation [presented forthe] M.Sc. Degree in Applied Solid State Physics.

by S. Sadek

  • 298 Want to read
  • 4 Currently reading

Published by Brighton Polytechnic, Department of Applied Physics in Brighton .
Written in English


Edition Notes

ContributionsBrighton Polytechnic. Department of Applied Physics.
ID Numbers
Open LibraryOL13744012M

Americium, found in many home smoke detectors, decays by alpha emission. The alpha particle ionizes surrounding air molecules, and ions produced conduct an electric current. Smoke particles block this process and the change in current triggers an alarm. Write the balanced nuclear equation for the decay of americium that will require least amount of energy and gives result close to ideal detonation cycle, as in [2], [6] and [7]. IV. REVIEW ON EXPERIMENTAL ANALYSIS A. Experimental Set-Up Fig 3: Experimental set up (The Swedish defence research agency) One example of a PDE is shown in Fig 3. This particular engine - which was assembled at one ofFile Size: KB. Millikan Oil Drop Apparatus Introduction 2 C where m is the mass and g is the acceleration due to gravity. To eliminate m from equation (3), the expression for the volume of a sphere and the density of the oil are used: where a is the radius of the droplet, and is the density of the oil. Substituting equation (4) into equation (3) yields:File Size: 1MB. Electrochemical Cells Objective Oxidation/reduction reactions find their most important use in the construction of voltaic cells (chemical batteries). In this experiment, several such cells will be constructed and their properties studied. Introduction Electrochemistry is the detailed study of electron-transfer (or oxidation/reduction File Size: KB.


Share this book
You might also like
Microfilm edition of Encyclopedia arctica

Microfilm edition of Encyclopedia arctica

The gift of tongues and other essays

The gift of tongues and other essays

Britains Haunted Heritage

Britains Haunted Heritage

Utahs living treasures

Utahs living treasures

Home study courses of inter[e]st to genealogists and local historians

Home study courses of inter[e]st to genealogists and local historians

69

69

Visit to Mr. Clowess printing office, 1833.

Visit to Mr. Clowess printing office, 1833.

Galileos Sidereus nuncius, or, A sidereal message

Galileos Sidereus nuncius, or, A sidereal message

First Greek lessons

First Greek lessons

Christianity as mystical fact and the mysteries of antiquity.

Christianity as mystical fact and the mysteries of antiquity.

Education and social change in Chile

Education and social change in Chile

Operations Manual for Machine Tool Technology

Operations Manual for Machine Tool Technology

Yugoslavia

Yugoslavia

Case worker.

Case worker.

Investment in Vietnam.

Investment in Vietnam.

Study of 127 electrostatic cylindrical analyser and application to energy analysis of ion guns by S. Sadek Download PDF EPUB FB2

According to Eq.(), the linear magnification coefficient at the Gaussian image plane of the ‐degree cylindrical sector analyzer is M x = cos π = − 1 and the dispersion coefficient is D K = r linear energy–resolving power in the spectrographic mode according to Eq. (a) is () R K = D K Δ x 0 = r 0 Δ x 0, as in the ‐degree homogeneous magnetic field [see by: 6.

High energy dispersion and fine focus of some electrostatic field with the plane of symmetry are used to make a compact energy analyser of high resolution.

The base of. A cylindrical electrostatic analyser was therefore designed, which can reduce the isotope background by a large factor. Introduction During recent years, mass spectrometry with accelerators has been developed [1] to determine the abundance of natural isotopes (te, la C, z6Al, 36 C1,etc) for dating : H.

Laurent, I. Brissaud, A. Sabir. A new method is described to produce useful electrical energy from DC electrostatic fields using a pyramid-shaped capacitor. The system uses no moving parts and no mechanical energy is introduced.

Also, when a pyramid-shaped electrode is charged with DC high voltage, a propulsive force is generated. This will allow the manufacture of vehicles capable of levitation and by:   The abundance of different ions produced by laser ion sources is usually analyzed by an electrostatic ion analyzer (EIA).

Ion current intensities in the range of several mA/cm2 at the position of the EIA have been achieved from the laser ion source developed by the Institute of Modern Physics; this indicates that a noticeable influence of space charge effect during the ion Cited by: 5. Analytical Estimation of the Electrostatic Field in Cylinder-Plane and (Emmanouil D.

F.) 2. RESEARCH METHOD It is known that the electric field distribution around two parallel cylindrical conductors of infinite length with identical cross-sections, can be calculated by assuming the presence of two equivalent lineFile Size: KB.

In this study, the direct current (DC) electric field effect on the diffusion-swirling flame dynamics and flame temperature profiles was investigated experimentally with the aim of establishing the feasibility of electric control of combustion in controlling the heat transfer rate and NO x formation.

It was observed that with an increase in voltage and change in polarity, the. A 'read' is counted each time someone views a publication summary (such as the title, abstract, and list of authors), clicks on a figure, or views or downloads the full-text.

negative ion beams with high current and power is the key component for the N-NBI system. Negative ion beams with a beam energy of 1MeV, beam current of 40A, and beam current density of 20mA/cm2 are required for the ITER-NBI[1–4]. To suppress the geometrical loss of neg-ative ion beams and heat loads in the beamline, NB duct.

An orbital ion trap mass analyzer employing hybrid magnetic-electric field was designed and simulated. The trap has a rotational symmetrical structure and the hybrid trapping field was created in a toroidal space between 12 pairs of sector detection electrodes.

Ion injection and ion orbital motion inside the trap were simulated using SIMION with a user Lua Author: Chongsheng Xu, Fangling Wu, Li Ding, Chuan-Fan Ding.

The abundance of different ions produced by laser ion sources is usually analyzed by an electrostatic ion analyzer (EIA). Ion current intensities in the range of several mA/cm(2) at the position of the EIA have been achieved from the laser ion source developed by the Institute of Modern Physics; this indicates that a noticeable influence of Cited by: 5.

Hiden Analytical Datasheets for Ion Beam Guns and Electron Beam Guns Ion beam guns and electron beam guns produce beams of electrons, ions or other particles for use in chemical and surface analysis, particle physics, resin curing or semiconductor manufacturing.

A spherical electrostatic analyzer was constructed for use with the Wisconsin cylindrical analyzer in accurate measurements of nuclear reaction energies.

The focusing properties of such an instrument have been described by Purcell. It has the unique feature of providing a large solid angle and high resolution for a very small angular spread of the reaction Cited by: Analysis is the process of measuring ____, ____, and ____ properties of chemical compounds so that the composition and quantities of the components can be determined.

Thermal Conductivity A(n) ____ analyzer is a gas analyzer that measures the concentration of a single gas in a sample by comparing its ability to conduct heat to that of a. Consider this energy model: Back voltage v is due to motion. dx dx dλ P m = f mu= f m = vi= i dt dt dx dλ Then, force is f m = i simply: dx.

Some caution here: this is the force due to the interaction with the coil -- It doesn t mean there may not be other forces. To find back voltage: run the system open circuited This will give the right back. Abstract. A rigorous theoretical study based on Zakharov Kuznetsov (ZK) equation of ion-acoustic solitary waves (IASWs), their stability analysis in a magnetized e-p-i plasma is presented.

The plasma model consists of inertial ions, magnetic field, electrons and positrons obeying q-nonextensive velocity ive perturbation method is used to derive ZK by: 5. Regular Articles Regular ArticlesCited by: 2.

Atomic Energy Levels: As Derived from the Analysis of Optical Spectra. Vol 1 only (Hydrogen to Vanadium) = Circular of the National Bureau of Standards on *FREE* shipping on qualifying offers.

Atomic Energy Levels: As Derived from the Analysis of Optical Spectra. Vol 1 only (Hydrogen to Vanadium) = Circular of the National Bureau of Standards Manufacturer: WashingtonNational Bureau of Standards only as a high-fidelity ion energy analyzer.

Preliminary check-out tests have been performed only to verify operation of the electrostatic energy analyzer. In the near future (summer '97) a time-of-flight technique will be integrated to provide species mass analysis in addition to energy analysis.

Electrostatic Energy Analyzer. The A novel linear ion trap mass analyzer built with four triangular electrodes, the triangular-electrode linear ion trap (TeLIT), has been built and its performance has been characterized.

The TeLIT has all the properties of a conventional LIT mass analyzer, performing ion trapping, mass analysis, and tandem mass spectrometry functions. The TeLIT was constructed with four identical Cited by: Experimental Analysis of Plasma Conditions in an Inverted Cylindrical Magnetron Sputtering System Honors Thesis submitted in Partial Fulfillment of the Requirements for the Honors Program for the Degree of Bachelor of Science In Mechanical Engineering Bradley Scott Handloser Project Advisor – Dr.

Matt Gordon Mechanical EngineeringAuthor: Bradley Handloser. We report the implementation of front-end higher energy collision induced dissociation (fHCD) on a bench-top dual pressure linear ion trap.

Software and hardware modifications were employed, described in detail vide-infra, to allow isolated ions to undergo collisions with ambient gas molecules in an intermediate multipole (q00) of the instrument.

Cited by: The optimum deflection angle of the electrodes in a cylindrical electrostatic analyzer with real slits has been discussed on the basis of numerically calculated electron by: Classification of Gas Discharges 2 The force on charge q is therefore F = − dU dx = −q dΦ dx = −qE x.

() Here, E x is the electric field and F is the Coulombic force. From this, it is easy to see that the electric field (force) is related to the electric potential by a derivative. The study of radiation interactions with key biological constituents at the molecular level, has shown an increasing interest in the last few years, in particular after the pioneering studies of Sanche and co-workers on the resonant formation of DNA strand breaks by low-energy electrons [1, 2].Such level of interactions has generated in the international community an Cited by: 3.

The following figure shows this plot, using the Morse potential. The shaded area in the well of the potential energy curve depicts the vibrational energy spacing as a grouping from quantum number v = 0 to v = 6. The energy well itself is quite deep and the characteristic asymmetry does not appear strongly in the lowest part of the well.

The present study has attempted to downscale a mass spectrometer in order to make it portable and enable onsite analysis with it. The development of a small mass spectrometer required the use of a compact pump whose displacement was small, decreasing the sensitivity of that spectrometer.

To get high sensitivity with a small mass spectrometer, we have integrated Cited by: Ion mass spectrometry was used to investigate discharges formed during high power impulse magnetron sputtering (HiPIMS) and direct current magnetron sputtering (DCMS) of a graphite target in Ar and Ar/N 2 ambient.

Ion energy distribution functions (IEDFs) were recorded in time-averaged and time-resolved mode for Ar +, C +, N 2 +, N +, and C x N y + by: electrostatic energy analyzer combined with a time-of-flight (TOF) mass spectrometer.

It was used successfully by King on the SPT and by Gulczinksi [5] on the P5 laboratory Hall thruster, providing a wealth of information on the ion energy and species composition of Hall thruster plumes. The instrument is mounted externally to PEPLs main.

The measurement and calibration of the O atom density in HiPIMS plasma were both performed in a stainless steel vacuum chamber with a magnetron source with a circular planar cathode (target), 10 cm in diameter and 5 mm thick, as described elsewhere [].The HiPIMS discharge operated in an Ar–O 2 gas mixture in a pressure range of 3–20 mTorr at a total gas Cited by: 3.

The energy distribution of sputtered and ionized metal atoms as well as ions from the sputtering gas is reported for a high power impulse magnetron sputtering (HIPIMS) discharge.

High power pulses were applied to a conventional planar circular magnetron Ti target. The peak power on the target surface was kW/cm(2) with a duty factor of about.

Aiming at high voltage electrostatic field of melting electron beam gun system, taking 30 kv 60 kw melting electron beam gun for example, the structure of the electric field and boundary conditions was designed.

And the mathematical model of the electric field was established. The method of numerical calculation was used to solve the mathematical model, and Matlab software was Author: Hai Lang Liu, Hang Li, Hai Hua Yu, Yi Ping Huang. Setting the magnitudes of the two forces equal, gives.

The factors of q cancel. Solving for the speed of the undeflected particles gives. (Eq. The speed of undeflected particles in a velocity selector) Question: Is the magnetic field in Figure directed into or out of the page. Answer: By the right-hand rule, to obtain a magnetic force directed up on aFile Size: KB.

Ion energy distribution functions (IEDFs) were recorded in time-averaged and time-resolved mode for Arþ,Cþ,N 2 þ,Nþ, and C xN y þ ions. An increase of N 2 in the sputter gas (keeping the deposition pressure, pulse width, pulse frequency, and pulse energy constant) results for the HiPIMS discharge in a significant increase in Cþ,Nþ, and.

The detection of carbon and oxygen in GaAs has been investigated by secondary ion mass spectrometry (SIMS). A reduction in carbon and oxygen background is achieved by means of a local pumping system using a 20 K‐cryopanel placed around the sample. Detection limits are 4× atoms/cm−3 for carbon, and 8× atoms/cm−3 for by: Reactive transition-metal (TM) nitride film growth employing bias-synchronized high power impulse magnetron sputtering (HiPIMS) requires a detailed knowledge of the time evolution of metal- and gas-ion fluxes incident at the substrate plane in order to precisely tune momentum transfer and, hence, provide the recoil density and energy necessary to eliminate film porosity Cited by: 6.

Chemical Analysis - complete elemental analysis from ppb to % using sophisticated instruments giving high precision and accuracy.

DE-ACNA with the U.S. Department of Energy and supported by the Site-Directed Research and Development Program. Center for Materials & Structures Computational Simulation and Experimental Study of Plastic Deformation in A36 Steel during High Velocity Impact ASME Verification and Validation Symposium, Las Vegas NV, Mayelectron beam production and application were carried using magnetron guns with a secondary-emission cathodes [].

The operating principle of these guns is based on the back bombardment of a cathode with primary electrons, the secondary electron accumulation in the crossed electric and magnetic fields, the electron.

(a) Sketch of the working principle of the pinhole camera with a cylindrical substrate holder. (b) Picture of the MFM, indicated parts are housing (1), pinhole (2), gasket (3), cylindrical substrate holder (4), cylindrical bracket (5), coated slide (6), measuring bar of 10cm (7).

together with the energy of the particles, by the gas transport. ight energy spectrometers (TOF-E) [5], magnetic spectrome-ters [6,7] and Bragg ionization chambers [8] or other pulse shape methods [9].

Out of the ion beam analysis methods ERDA is one of the more demanding in terms of detector design. There is a need for simultaneous measurements of two or more.Sputter Coating Technical Brief 6 Issue 1 3 Glow Discharge.

Once the condition for a sustained discharge is met, the tube exhibits the characteristic glow discharge, so called because of the associated luminous glow. It has been established that free ions and electrons are attracted to opposite electrodes producing a discharge - however for aFile Size: KB.Full text of "Inorganic Mass Spectrometry Fundamentals and Applications" See other formats.